The DTU162 keeps both spindle cooling water and cutting water at a constant temperature and suitable pressure. It thereby helps manage expansion, contraction, and other undesirable phenomena caused by water temperature fluctuation.
By circulating used cutting water and precipitation filtration of water-borne debris, the DTU162 significantly reduces water consumption and environmental impact. Further, the refrigerant used in DTU162 is a completely non-ozone-depleting hydrofluorocarbon (R-407C).
The efficient design of DTU162’s interior makes a very small unit footprint possible.
Use of long 20’’ filters allows for less frequent replacements. Interior layout designed for maximum the simplicity of regular maintenance.
Specification | Unit | Cooling water line | Cutting water line |
---|---|---|---|
Range required to guarantee accuracy | ℃ | 20 ~ 25 | 20 ~ 27 and within 2℃ of the spindle coolant setting |
Temperature accuracy | ℃ | 1 | 1 |
Cooling efficiency | kW | 0.6 | 0.6 |
Heating efficiency | kW | 0.6 | 2 |
Flow rate | L/min | 6 | 10 |
Circulation method | - | Recirculation type | Recirculation type |
Equipment dimensions (W×D×H) | mm | 430 × 900 × 1,500 | |
Equipment weight | kg | Approx.240 when full |
*Product appearance, features, specifications, and other details may change due to technical
modifications.
*Please read the standard specification sheet thoroughly before use.